Scope of Application:
The Ionic Balance Method is essentially a calculation carried out using the results of 10 individual analyses. The methods for these analyses therefore form part of the Ionic Balance Method. The parameters analysed for are:
Alkalinity Nitrate
Sulphate Nitrite
Sodium Potassium
Calcium Magnesium
pH Conductivity
Chloride
Others
The method is applicable to water and effluent matrices.
Technique:
Titrimetry, Ion Chromatography, Conductivity probe, ICP-MS
Reference method:
SCA method, The Examination of Waters and Associated MaterialsUSEPA Method 9056, 6020
Limit of Detection:
El. Conductivity- 5.0uS/cm
Alkalinity as CaCO3- 3mg/L
Chloride- 0.1mg/L
Sulphate- 0.05mg/L
Nitrate- 0.02mg/L
Nitrite- 0.02mg/L
Sodium- 0.2mg/L
Potassium- 0.2mg/L
Calcium- 0.2mg/L
Magnesium- 0.2mg/L
Sample required:
Waters : 500ml
Container:
Poly
Notes:
1. MDLs may be affected by sample matrix interferences, dilutions
2. The list of determinands may vary: call to confirm.