Phenols by GC/MS
Technique:GC/MS SIM
Reference method:Derived from USEPA Method 8041, 604
Limit of Detection:Waters: 0.1-1.0ug/L
Soils: 5-80ug/Kg
XAD Tube: 1-10ug/Tube
Sample required:Waters : 500ml
Soils : 30g
Container:Glass
List of Compounds:4-chloro-3-methylphenol
2-Chlorophenol
2,4-Dichlorophenol
2,6-Dinitrophenol
2,4-Dimethylphenol
4,6-Dinitro-2-methylphenol
2,4-Dinitrophenol
2-Methylphenol
4-Methylphenol
2-(1-methylpropyl)-4,6-dinitrophenol
2-Nitrophenol
4-Nitrophenol
Pentachlorophenol
Phenol
2,3,4,6-Tetrachlorophenol
2,4,5-Trichlorophenol
2,4,6-Trichlorophenol
Notes:1. MDLs may be affected by sample matrix interferences, dilutions
2. The list of determinands may vary: call to confirm